Products

PRODUCT CENTER
+
  • GGD型交流低压配电柜.jpg

GGD type AC low voltage distribution cabinet

Scope of application GGD low-voltage fixed complete switchgear (hereinafter referred to as power distribution cabinet)

Classification:

Intelligent complete equipment

Key words: power transformer Intelligent complete equipment New energy box substation intelligent electric


message

Product Description

Scope of application
GGD low-voltage fixed complete switchgear (hereinafter referred to as power distribution cabinet) is suitable for power users such as power plants, substations, industrial and mining enterprises as power distribution systems with AC 50Hz(60Hz), rated working voltages 380V(400V) and (660V) and rated currents up to 3150A as power, lighting and power distribution equipment for power conversion, distribution and control. The product has high breaking capacity, good dynamic thermal stability, rated short-time withstand current up to 50kA. The electrical scheme is flexible, convenient combination, strong practicability, novel structure and high protection level.
The distribution cabinet is a type test and has passed the national compulsory product 3C certification. The product conforms to the "low-voltage switchgear and control equipment", "low-voltage switchgear and control equipment" and other standards.
 
Model
Use of the environment
> The ambient air temperature does not exceed 40 ℃, and the average value measured within 24 hours does not exceed 35 ℃, and the minimum ambient air temperature is -5 ℃;
> The altitude of the installation site does not exceed 2000m;
> The surrounding air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors or salt spray;
> Atmospheric conditions: the air is clean, and the relative humidity must not exceed 50% when the maximum temperature is +40 ℃. At lower temperatures, greater relative humidity is permitted. For example, the relative humidity is 90% at +20 ℃. However, it should be considered that due to temperature changes, there may be occasional moderate suspicious dew.
> When the equipment is installed, the inclination of the vertical plane does not exceed 5 °;
> The equipment should be installed in a place without severe vibration and impact;
> Note: Users can negotiate with our company when they have special requirements.
 
Outline installation dimension
Technical parameters

Other Products

View Details

SC(B)10-10kV series epoxy resin cast dry-type power transformer

The epoxy resin casting dry-type transformer produced by our company is developed by introducing domestic and foreign technology

View Details

SC(B)10-35kV Series Epoxy Insulation Dry-Type Power Transformer

SC(B)10-35kV series dry-type transformers are suitable for special power occasions that need to be directly converted from 35kV grid voltage

View Details

SG(B)10 Series Non-Encapsulated Coil Three-Phase Dry-Type Power Transformer

The non-encapsulated coil three-phase dry-type power transformer produced by our company has the advantages of safety,

What kind of help do I want to give you?

Want To Know More?

Submission